Computer lights several common troubleshooting
Classification:
summary description]
Computer lamps are an important class of lamps. In performing arts activities, it plays a role in setting off the atmosphere, rendering the stage mood, and mobilizing the mood of the scene, so it is widely used.
Computer lamps are an important class of lamps. In performing arts activities, it plays a role in setting off the atmosphere, rendering the stage mood, and mobilizing the mood of the scene, so it is widely used.
Computer lamp is a kind of more precise equipment, which integrates electronics, machinery and optics, and has high requirements for environment, transportation and use, so its failure rate is also high. Here, combined with the failure phenomenon, the possible causes are analyzed for the reference of relevant personnel.
No response when starting up
1. Whether the power supply is normal and whether the power cord of the lamp falls off;
2. Whether the safety tube of the lamp is burnt out;
3. Whether the switching power supply of the lamp has an output voltage.
Boot does not light bubble
1. First, judge the quality of the bulb, whether the distance between the two poles in the bulb sphere is too long, whether there is air leakage (a piece of Milky White in the bulb), and check whether the bulb is loose.
2. When the lamp is in the state of point bubble, measure whether the main board point bubble voltage output is normal, and the normal situation is generally 10~12 volts.
3. If the above two points are correct, measure whether there is an AC voltage output of about 380V at the moment of the electronic ballast spot bubble. If there is an output, it indicates that the ballast is good, so that it can be directly determined that there is a problem with the trigger.
After working for a period of time, the lamp will automatically reset
1. The output voltage of the switching power supply is unstable;
2. The cable in the line is loose or the line is not compressed, resulting in poor contact and automatic reset.
Automatic bulb extinguishing
1. The bulb goes out and automatically lights up after a period of time. Check whether the heat dissipation system is working normally. If the heat dissipation system fails, the temperature in the lamp body will be too high, and the temperature control switch will automatically trip to ensure the safe use of the lamp. When the lamp is turned off by electronic lighting, it will automatically light up when the temperature of the lamp body decreases.
2. After the bulb is extinguished, the bulb cannot be automatically lit: due to the problem of the bulb itself, the surface of the bulb sphere is albino and the inside is black. After a period of time, the bulb will be extinguished (the life of the bulb is over).
3. The lamp will also have automatic protection when there is no control signal for a long time, and it will automatically light up after the signal is turned on.
Pattern wheel, color wheel, prism, focusing, magnification appear stuck, jitter, out of step
1. The blocking is generally caused by mechanical reasons (except CMY color film). When a CMY color film is broken and falls off, thus affecting the normal operation of other color films, the blocking phenomenon of color film will occur at this time: such as the pattern plate, the deformation of the color plate, the loosening of the screws of the fixing parts, the ejection of the compression spring of the fixed pattern, etc., which will all lead to the blocking.
2. Jitter and out-of-step: the screw is loose or falls off, the chip of its channel on the main board is burnt out, the motor wire is in poor contact, broken skin and short circuit to the ground, and the motor itself is a problem.
Horizontal and vertical (X/Y axis) step-out, no positioning
1, too much dust on the optical coupling, resulting in infrared light can not be controlled in place;
2. The optical coupling plate is damaged, and the distance between the optical coupling plate and the optical coupling plate is improperly adjusted (when excluding, the optical coupling plate should be in the middle of the optical coupling plate, and there should be no scraping, touching or beating);
The above is an analysis of the causes of some common failures. In fact, to reduce the occurrence of failures, usual maintenance is essential. The following is a brief introduction to some matters needing attention in daily maintenance:
1, optical components, first with a vacuum cleaner or air bag to gently blow away the surface dust, with odorless cotton paper or soaked in water to wipe off the granular matter, with a cotton cloth soaked in ethyl alcohol or odorless paper to remove dust and residue, with distilled water to do the final cleaning, and then dry with a soft cotton cloth;
2, with coated color, pattern and optical lens parts, because the surface of the coating layer is very brittle, it is easy to scratch, so do not use destructive solvents for cleaning;
3, to regularly replace the air filter cotton, so that it is in the best state of ventilation, training to enhance the heat dissipation of lamps;
4, the computer light to light, to avoid collisions, falls, etc;
5, be careful not to use in the wind and dust more occasions;
6, the power supply voltage should be stable, long-term power supply voltage in about 240 volts to consider the use of regulated power supply;
7. After the performance, use the console to extinguish the bubble, and let the lamp continue to work for a period of time without cutting off the power supply (let the fan in the lamp continue to work to reduce the temperature in the lamp body);
8. After the liquidity performance, it should be put into a special flight box to prevent moisture and shock. The fixed computer lights should be protected from dust and impact.